Special Cables

Unshielded - Double insulated PVC single conductor

Application

these cables are ideally suited for use in drag chains, and also for use in handling devices, robots, and nearly any area requiring flexible used and free motion.

Construction

Bare copper, extra fine wire conductor to DIN VDE 0295 cl. 6 and IEC 60228 cl. 6;

PVC insulation, green-yellow;

PVC jacket compound TM2;

Jacket color gray.

Temperature range: flexing -5°C to +80°C;fixed installation -40°C to +80°C

Nominal voltage:U0/U 600/1000 V

A.C. test voltage, 50 Hz: 3000 V

Minimum bending radius: for flexible installation; approx. 5x cable Ø

Insulation resistance: min. 20 MOhm x km

Properties 

PVC self-extinguishing and flame retardant according to DIN VDE 0482 part 265-2-1/ EN 50265-2-1/ IEC 60332-1

(equivalent DIN VDE 0472 part 804 test method B);

Chemical resistance see table Technical Information;

Unshielded - Double insulated,PVC single conductor.

Unshielded - Double insulated, PVC single conductor

Conductors x cross-sec. mm² Outer
Diameter
Copper weight
kg/km
Weight
ca. kg/km
AWG
1x2.5 4.5 24.0 42.0 14
1x4 5.6 38.4 58.0 12
1x6 6.1 57.6 85.0 10
1x10 8.0 96.0 130.0 8
1x16 9.8 154.0 190.0 6
1x25 11.8 240.0 280.0 4
1x35 12.9 336.0 400.0 2
1x50 14.6 480.0 520.0 1
1x70 17.5 672.0 720.0 2/0
1x95 20.0 912.0 1050.0 3/0
1x120 21.6 1152.0 1220.0 4/0
1x150 23.5 1440.0 1500.0 300 kcmil
1x185 25.7 1776.0 1940.0 350 kcmil
1x240 29.5 2304.0 1675.0 500 kcmil
1x300 32.5 2880.0 3300.0 600 kcmil